Sign In | Join Free | My himfr.com
Home > Fluid Mechanics Lab Equipments >

SCADA Fluid Mechanics Lab Equipments 12m3/H Heat Exchanger Equipment 2cbm

    Buy cheap SCADA Fluid Mechanics Lab Equipments 12m3/H Heat Exchanger Equipment 2cbm from wholesalers
     
    Buy cheap SCADA Fluid Mechanics Lab Equipments 12m3/H Heat Exchanger Equipment 2cbm from wholesalers
    • Buy cheap SCADA Fluid Mechanics Lab Equipments 12m3/H Heat Exchanger Equipment 2cbm from wholesalers

    SCADA Fluid Mechanics Lab Equipments 12m3/H Heat Exchanger Equipment 2cbm

    Ask Lasest Price
    Brand Name : SSEDU
    Model Number : ZM9109
    Certification : ISO9001
    Price : USD1000 to 2000
    Payment Terms : T/T, L/C, Western Union
    Supply Ability : 2000 sets per year
    Delivery Time : 30 days
    • Product Details
    • Company Profile

    SCADA Fluid Mechanics Lab Equipments 12m3/H Heat Exchanger Equipment 2cbm

    ZM9109 Educational Training Equipment Fluids Engineering Training Equipment Trainer For Various Heat Exchangers


    examination and comparison of various heat exchanger types

    five different types of heat exchangers included in the scope of delivery

    finned heat exchanger with fan

    operating mode (parallel flow or counter flow) selectable via valves

    flow rates adjustable via valves

    electromagnetic flow meter

    digital displays for temperature, pressure differences and flow rate

    Control Interface Box and Data Acquisition Board part of SCADA system

    system.

    Technical Data Base service unit:

    Stainless steel tank (30 l), equipped with:

    Electric heating element (3000 W) with thermostat (70 °C), to heat the water, computer controlled.

    Temperature sensor (“J” type) to measure the water temperature.

    Level switch to control the water level in the tank.

    Stainless steel cover to avoid the contact with hot water. The cover should have a hole that allows to visualize the water level and also to stuff the tank.

    Draining water valve.

    Centrifugal pump with speed control from computer, range: 0 - 3 l/min.

    Two flow sensors, one for hot water and the other for cold water, range: 0.25 - 6.5 l/min.

    Control valves for the cold and hot water.

    Four ball valves that, depending on how manipulated, could give co¬current or counter-current flux in the exchanger.

    Two ball valves to control and drain the hot water of the base unit. Pressure regulator to avoid the introduction of too much pressure in the exchangers, tared at 0.6 bar.

    Four flexible tubes to connect with the different exchangers.

    Dimensions: 1100 x 630 x 500 mm approx. (43.3 x 24.8 x 19.68 inches approx.). Weight: 50 kg approx. (110.2 pounds approx.).

    With

    Concentric Tube Heat Exchanger:

    Exchange length: L = 2 x 0.5 = 1 m.

    Internal tube:

    Internal diameter: Dint = 16 • 10-3 m.

    External diameter: Dext = 18 • 10-3 m.

    Thickness = 10-3 m.

    Heat transfer internal area: Ah = 0.0503 m2.

    Heat transfer external area: Ac = 0.0565 m2.

    External tube:

    Internal diameter: Dint = 26 • 10-3 m.

    External diameter: Dext = 28 • 10-3 m.

    Thickness = 10-3 m.

    Six temperature sensors (“J” type)

    Extended Concentric Tube Heat Exchanger:

    Exchange length: L=4x1=4 m.

    Internal tube:

    Internal diameter: Dint = 16 • 10-3 m.

    External diameter: Dext = 18 • 10-3 m.

    Thickness = 10-3 m.

    Heat transfer internal area: Ah = 0.0503 m2.

    Heat transfer external area: Ac = 0.0565 m2.

    External tube:

    Internal diameter: Dint = 26 • 10-3 m.

    External diameter: Dext = 28 • 10-3 m.

    Thickness = 10-3 m.

    Ten temperature sensors (”J” type)

    Plate Heat Exchanger Maximum flow: 12m3/h.

    Maximum work pressure: 10 bar.

    Maximum work temperature: 100 °C.

    Minimum work temperature: 0 °C.

    Maximum number of plates: 20.

    Internal circuit capacity: 0.176 l.

    External circuit capacity: 0.22 l.

    Area: 0.32 m2.

    Four temperature sensors (“J” type)

    Extended Plate Heat Exchanger

    Maximum flow: 12 m3/h.

    Maximum work pressure: 10 bar.

    Maximum work temperature: 100 °C.

    Minimum work temperature: 0 °C.

    Maximum number of plates: 20.

    Internal circuit capacity: 0.176 l.

    External circuit capacity: 0.22 l.

    Area: 0.32 m2.

    Ten temperature sensors (”J” type)

    Shell & Tube Heat Exchanger

    Four segmented baffles located transversaly in the shell. Exchange length of the shell and each tube: L = 0.5 m. Internal tube (21 tubes):

    Internal diameter: Dint= 8 • 10-3 m.

    External diameter: Dext = 10 • 10-3 m.

    Thickness = 10-3 m.

    Internal heat transfer area: Ah= 0.0126 m2.

    External heat transfer area: Ac= 0.0157m2.

    Shell:

    Internal diameter: Dint,c= 0.148 m.

    External diameter: Dext,c= 0.160 m.

    Thickness = 6 • 10-3 m.

    Seven temperature sensors ("J" type), for measuring cold and hot water temperatures at different points of the exchanger.

    Jacketed Vessel Heat Exchanger:

    Anodized aluminum frame and panels made of painted steel.

    Main metallic elements made of stainless steel.

    Diagram in the front panel with distribution of the elements similar to the real one.

    Constituted of a vessel.

    Vessel total volume: 14 l.

    Interior vessel volume: 7 l approx.

    Jacket volume: 7 l approx.

    Overflow or a pipe allows the exit of the water in the vessel through its upper part to maintain a constant flow during the process with a continuous supply.

    Jacket surrounds the vessel through where hot water flows.

    Electric stirrer.

    Five temperature sensors ("J" type)

    Coil Vessel Heat Exchanger

    Anodized aluminum frame and panels made of painted steel.

    Main metallic elements made of stainless steel.

    Diagram in the front panel with distribution of the elements similar to the real one.

    Formed by a pvc-glass vessel, volume: 14 l.

    Overflow or pvc-glass tube lets the output of water from the vessel in the upper part in order to maintain the flow constant for continue supply process.

    Copper coil where the water circulates:

    Dint= 4.35 mm.

    Dext = 6.35 mm.

    Total length of the tube that forms the coil: 1.5 m.

    Electric stirrer.

    Five temperature sensors ("J" type)

    Turbulent Flow Heat Exchanger

    With Anodized aluminum frame and panels made of painted steel.

    With Main metallic elements made of stainless steel.

    Diagram in the front panel with distribution of the elements similar to the real one.

    Formed by two copper concentric tubes with hot water circulating through the internal tube and cold water circulating through the annular space.

    The exchanger should have 4 equal sections of 500 mm each one, where the heat transfer takes place.

    Exchange length: L = 4 x 0.5 = 2 m.

    Internal tube:

    Internal diameter: Dint = 8 • 10-3 m.

    External diameter: Dext= 10 • 10-3 m.

    Thickness = 10-3 m.

    Internal heat transfer area: Ah= 0.0377 m2.

    External heat transfer area: Ac= 0.0471 m2.

    External tube:

    Internal diameter: Dint,c =13 • 10-3 m.

    External diameter: Dext,c = 15 • 10-3 m.

    Thickness = 10-3 m.

    Twelve temperature sensors: ("J" type)

    Cross Flow Heat Exchanger

    Anodized aluminum frame and panels made of painted steel.

    Main metallic elements made of stainless steel.

    Diagram in the front panel with distribution of the elements similar to the real one.

    Poly methyl methacrylate (PMMA) rectangular duct of 800 x 200 x 200 mm.

    Radiator located across the air duct.

    The fins of the radiator should made of aluminum and have a heat transfer area of ​​35000 mm2.

    Axial fan with speed control from computer (PC). It should provide a maximum air velocity of 3 m/s.

    Four "J" type temperature sensors to measure input and output water and air temperatures.

    Velocity sensor to measure air velocity, range: 0 - 4 m/s.

    Two ball valves.

    Installation & Basic operational training included


    Product Details and Warranty
    We supply suitable spare pats according to experiment requirement, our products take aluminum structure, A4 paper dimension aluminum and plastic hanging box structure.
    We supply 3 years warranty time.

    Packaging & Delivery
    Package details: plastic film+ plastic foam + plywood box with pallet, and for equipment dimension less than 1CBM, we supply plastic film+ plastic foam+ fine carton.

    Arrange delivery within 45 days upon receipt of payment.

    Please see below photo for detailed package.


    SCADA Fluid Mechanics Lab Equipments 12m3/H Heat Exchanger Equipment 2cbmSCADA Fluid Mechanics Lab Equipments 12m3/H Heat Exchanger Equipment 2cbmSCADA Fluid Mechanics Lab Equipments 12m3/H Heat Exchanger Equipment 2cbmSCADA Fluid Mechanics Lab Equipments 12m3/H Heat Exchanger Equipment 2cbm


    Training Room Photo
    SCADA Fluid Mechanics Lab Equipments 12m3/H Heat Exchanger Equipment 2cbmSCADA Fluid Mechanics Lab Equipments 12m3/H Heat Exchanger Equipment 2cbmSCADA Fluid Mechanics Lab Equipments 12m3/H Heat Exchanger Equipment 2cbmSCADA Fluid Mechanics Lab Equipments 12m3/H Heat Exchanger Equipment 2cbm



    Company Information

    We supply professional educational training equipment and technical teaching equipment, which has been widely applied in Engineering Universities, Polytechnics, Technical Institute, Vocational Schools as well as Industry workforce Development Programs and Training Center. Our products allow students to learn and experiment through valuable hands-on experience, and the technology covered by our training equipment provides knowledge, experiments and didactic skills development that are of critical importance to today´s and tomorrow´s careers.


    SCADA Fluid Mechanics Lab Equipments 12m3/H Heat Exchanger Equipment 2cbmSCADA Fluid Mechanics Lab Equipments 12m3/H Heat Exchanger Equipment 2cbmSCADA Fluid Mechanics Lab Equipments 12m3/H Heat Exchanger Equipment 2cbm
    Photo for Clients Visiting Factory

    SCADA Fluid Mechanics Lab Equipments 12m3/H Heat Exchanger Equipment 2cbm

    SCADA Fluid Mechanics Lab Equipments 12m3/H Heat Exchanger Equipment 2cbm

    SCADA Fluid Mechanics Lab Equipments 12m3/H Heat Exchanger Equipment 2cbm

    SCADA Fluid Mechanics Lab Equipments 12m3/H Heat Exchanger Equipment 2cbm


    Service

    We supply supply7*24 hours service, customer design service, OEM service, buyer label service. With professional engineers team and sales team, we assure you good product quality.


    Certificate
    Our products takes ISO9001 product management system.

    No.Feature NameDetails
    1Customer designYes
    2Warranty1 year, 2 years, 3 years or 5 years according to client requirements
    3PackagePlastic film+ carton+ Fine plywood
    4Products standardInternational didactic equipment standard
    5Application rangeEducational equipment for university, college, vocational training centers
    6Company philosophySupply best quality Chinese products to the worldwide schools.
    7Self owned brandShouldshine, SSEDU, JSS.
    8Production timeFrom 10 days to 60 days according to different items

    Quality SCADA Fluid Mechanics Lab Equipments 12m3/H Heat Exchanger Equipment 2cbm for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Jinan Should Shine Didactic Equipment Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)