    Brand Name : ShouldShine
    Model Number : SR3005
    Certification : ISO9001
    Price : negociate
    Payment Terms : L/C, D/A, D/P, Western Union, T/T
    Supply Ability : 5000 sets per year
    Delivery Time : 35 days
    • Product Details
    • Company Profile

    Piping System Convection Heat Transfer Apparatus With Installation Technology Losses

    SR3005 Installation technology: losses in a pipe system Thermal Lab Equipment Didactic Equipment

    1. Technical data


    Brand: ShouldShine


    Model:SR3005


    Learning Objectives / Experiments


    - pressure curve in a closed pipe system with circulation pump


    - influence of pipe diameter, flow velocity, change in


    cross-section and pipe fittings on the pressure losses


    - determination of pump characteristics, system characteristics and the operating point


    2. Specification


    [1] investigation of the pressure losses at contractions, pipe angles, pipe bends, valves and fittings and pipe elements of different diameter


    [2] pipe elements are commercially standard components in heating and sanitary engineering


    [3] clear panel mounted on a sturdy, movable frame


    [4] closed water circuit with pump and tank


    [5] integrated bleed valve on manometer and in the pipe section


    [6] flow measurement using rotameter


    [7] measurement of the pressure distribution at 13 pressure measuring points, display with 13 tube


    manometers


    3. Technical Data


    Pump - 3 stages - max. flow rate: 4,5m³/h - max. head: 6m


    Tank: approx. 5L


    Measuring range - flow rate: 100...1000L/h - pressure: 1600mmWC


    Dimensions and Weight LxWxH: 1900x700x2020mm Weight: approx. 340kg


    Required for Operation


    230V, 50Hz, 1 phase


    Arrange delivery within 45 days upon receipt of payment.

    Please see below photo for detailed package.


    Piping System Convection Heat Transfer Apparatus With Installation Technology LossesPiping System Convection Heat Transfer Apparatus With Installation Technology LossesPiping System Convection Heat Transfer Apparatus With Installation Technology LossesPiping System Convection Heat Transfer Apparatus With Installation Technology Losses


    Training Room Photo
    Piping System Convection Heat Transfer Apparatus With Installation Technology LossesPiping System Convection Heat Transfer Apparatus With Installation Technology LossesPiping System Convection Heat Transfer Apparatus With Installation Technology LossesPiping System Convection Heat Transfer Apparatus With Installation Technology Losses



    Company Information

    We supply professional educational training equipment and technical teaching equipment, which has been widely applied in Engineering Universities, Polytechnics, Technical Institute, Vocational Schools as well as Industry workforce Development Programs and Training Center. Our products allow students to learn and experiment through valuable hands-on experience, and the technology covered by our training equipment provides knowledge, experiments and didactic skills development that are of critical importance to today´s and tomorrow´s careers.


    Piping System Convection Heat Transfer Apparatus With Installation Technology LossesPiping System Convection Heat Transfer Apparatus With Installation Technology LossesPiping System Convection Heat Transfer Apparatus With Installation Technology Losses
    Photo for Clients Visiting Factory
    Piping System Convection Heat Transfer Apparatus With Installation Technology Losses

    Piping System Convection Heat Transfer Apparatus With Installation Technology Losses

    Piping System Convection Heat Transfer Apparatus With Installation Technology Losses

    Piping System Convection Heat Transfer Apparatus With Installation Technology Losses
    Service

    We supply supply7*24 hours service, customer design service, OEM service, buyer label service. With professional engineers team and sales team, we assure you good product quality.


    Certificate
    Our products takes ISO9001 product management system.

    No.Feature NameDetails
    1Customer designYes
    2Warranty1 year, 2 years, 3 years or 5 years according to client requirements
    3PackagePlastic film+ carton+ Fine plywood
    4Products standardInternational didactic equipment standard
    5Application rangeEducational equipment for university, college, vocational training centers
    6Company philosophySupply best quality Chinese products to the worldwide schools.
    7Self owned brandShouldshine, SSEDU, JSS.
    8Production timeFrom 10 days to 60 days according to different items